FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package de.medizininformatikinitiative.kerndatensatz.icu#2025.0.0-ballot.1 (62 ms)

Package de.medizininformatikinitiative.kerndatensatz.icu
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=de.medizininformatikinitiative.kerndatensatz.icu@2025.0.0-ballot.1&canonical=https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/atemfrequenz
Url https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/atemfrequenz
Version 2025.0.0
Status active
Name SD_MII_ICU_Atemfrequenz
Title SD MII ICU Atemfrequenz
Experimental False
Type Observation
Kind resource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
http://fhir.de/StructureDefinition/observation-de-vitalsign-atemfrequenz Observation-Profil Atemfrequenz
https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/ValueSet-Unit-equivalent-UCUM-breaths_per-minute VS MII ICU Unit equivalent UCUM breaths per minute


Narrative

Note: links and images are rebased to the (stated) source

No human-readable text provided in this case.

Source

{
  "resourceType" : "StructureDefinition",
  "id" : "sd-mii-icu-muv-atemfrequenz",
  "text" : {
    "status" : "empty",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">No human-readable text provided in this case.</div>"
  },
  "url" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/atemfrequenz",
  "version" : "2025.0.0",
  "name" : "SD_MII_ICU_Atemfrequenz",
  "title" : "SD MII ICU Atemfrequenz",
  "status" : "active",
  "fhirVersion" : "4.0.1",
  "mapping" : [
    {
      "identity" : "workflow",
      "uri" : "http://hl7.org/fhir/workflow",
      "name" : "Workflow Pattern"
    },
    {
      "identity" : "sct-concept",
      "uri" : "http://snomed.info/conceptdomain",
      "name" : "SNOMED CT Concept Domain Binding"
    },
    {
      "identity" : "v2",
      "uri" : "http://hl7.org/v2",
      "name" : "HL7 v2 Mapping"
    },
    {
      "identity" : "rim",
      "uri" : "http://hl7.org/v3",
      "name" : "RIM Mapping"
    },
    {
      "identity" : "w5",
      "uri" : "http://hl7.org/fhir/fivews",
      "name" : "FiveWs Pattern Mapping"
    },
    {
      "identity" : "sct-attr",
      "uri" : "http://snomed.org/attributebinding",
      "name" : "SNOMED CT Attribute Binding"
    }
  ],
  "kind" : "resource",
  "abstract" : false,
  "type" : "Observation",
  "baseDefinition" : "http://fhir.de/StructureDefinition/observation-de-vitalsign-atemfrequenz",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Observation.id",
        "path" : "Observation.id",
        "mustSupport" : true
      },
      {
        "id" : "Observation.meta",
        "path" : "Observation.meta",
        "mustSupport" : true
      },
      {
        "id" : "Observation.identifier",
        "path" : "Observation.identifier",
        "mustSupport" : true
      },
      {
        "id" : "Observation.status",
        "path" : "Observation.status",
        "mustSupport" : true
      },
      {
        "id" : "Observation.category",
        "path" : "Observation.category",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code",
        "path" : "Observation.code",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding",
        "path" : "Observation.code.coding",
        "min" : 2,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc",
        "path" : "Observation.code.coding",
        "sliceName" : "loinc",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc.system",
        "path" : "Observation.code.coding.system",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc.code",
        "path" : "Observation.code.coding.code",
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:snomed",
        "path" : "Observation.code.coding",
        "sliceName" : "snomed",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "system" : "http://snomed.info/sct",
          "code" : "86290005"
        }
      },
      {
        "id" : "Observation.subject",
        "path" : "Observation.subject",
        "mustSupport" : true
      },
      {
        "id" : "Observation.encounter",
        "path" : "Observation.encounter",
        "mustSupport" : true
      },
      {
        "id" : "Observation.effective[x]",
        "path" : "Observation.effective[x]",
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x]",
        "path" : "Observation.value[x]",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "type",
              "path" : "$this"
            }
          ],
          "ordered" : false,
          "rules" : "open"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x]:valueQuantity",
        "path" : "Observation.value[x]",
        "sliceName" : "valueQuantity",
        "min" : 1,
        "patternQuantity" : {
          "unit" : "breaths per minute"
        }
      },
      {
        "id" : "Observation.value[x]:valueQuantity.value",
        "path" : "Observation.value[x].value",
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x]:valueQuantity.unit",
        "path" : "Observation.value[x].unit",
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x]:valueQuantity.system",
        "path" : "Observation.value[x].system",
        "mustSupport" : true
      },
      {
        "id" : "Observation.value[x]:valueQuantity.code",
        "path" : "Observation.value[x].code",
        "mustSupport" : true,
        "binding" : {
          "strength" : "required",
          "valueSet" : "https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/ValueSet-Unit-equivalent-UCUM-breaths_per-minute"
        }
      },
      {
        "id" : "Observation.dataAbsentReason",
        "path" : "Observation.dataAbsentReason",
        "mustSupport" : true
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.